Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3QPW

PFKFB3 in complex with Aluminum Tetrafluoride

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCAMD BEAMLINE GCPCC
Synchrotron siteCAMD
BeamlineGCPCC
Temperature [K]100
Detector technologyCCD
Collection date2007-04-26
DetectorMAR CCD 165 mm
Wavelength(s)1.3808
Spacegroup nameP 65 2 2
Unit cell lengths102.709, 102.709, 257.044
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution30.000 - 2.250
R-factor0.20162
Rwork0.200
R-free0.24216
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.022
RMSD bond angle1.814
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareREFMAC (5.2.0019)
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.330
High resolution limit [Å]2.2502.250
Number of reflections38530
Completeness [%]99.598.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.530000 mM Tris-HCl, pH 7.5, 20-25% ethylene glycol, 200-400mM Tartaric Acid, 5% glycerol,12% polyethylene glycol 4000, VAPOR DIFFUSION, SITTING DROP, temperature 300K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon