Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3D49

Thrombin Inhibition

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]110
Detector technologyCCD
Collection date2007-06-30
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths70.350, 71.480, 72.470
Unit cell angles90.00, 100.39, 90.00
Refinement procedure
Resolution10.000 - 1.500
R-factor0.207
Rwork0.198
R-free0.23670
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1h8d
RMSD bond length0.011
RMSD bond angle0.028
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.530
High resolution limit [Å]1.5001.500
Number of reflections54430
<I/σ(I)>29.734.94
Completeness [%]97.086.8
Redundancy2.92.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5277Phosphate Buffer, Sodium Chloride, PEG 8000 , pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K