Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2ZFR

Exploring thrombin S3 pocket

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2007-12-13
DetectorMAR CCD 165 mm
Wavelength(s)0.9184
Spacegroup nameC 1 2 1
Unit cell lengths70.300, 71.500, 72.300
Unit cell angles90.00, 100.40, 90.00
Refinement procedure
Resolution10.000 - 1.850
R-factor0.1931
Rwork0.181
R-free0.25330
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)1h8d
RMSD bond length0.006
RMSD bond angle0.023
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.880
High resolution limit [Å]1.8501.850
Number of reflections28636
<I/σ(I)>14.42.3
Completeness [%]95.296.4
Redundancy2.72.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5277Phosphate buffer, sodium chloride, PEG8000, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K

224931

PDB entries from 2024-09-11

PDB statisticsPDBj update infoContact PDBjnumon