2ZDA

Exploring Thrombin S1 pocket

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]110
Detector technologyCCD
Collection date2007-06-28
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths70.300, 71.500, 72.400
Unit cell angles90.00, 100.50, 90.00
Refinement procedure
Resolution10.000 - 1.730
R-factor0.1796
Rwork0.172
R-free0.22830
Structure solution methodAB INITIO PHASING
Starting model (for MR)1h8d
RMSD bond length0.008
RMSD bond angle0.025
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSHELX
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.760
High resolution limit [Å]1.7301.730
Number of reflections35607
<I/σ(I)>14.83.3
Completeness [%]97.693.1
Redundancy2.92.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5277Phosphate Buffer, Sodium Chloride, PEG 8000, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K