2Y21
The mechanisms of HAMP-mediated signaling in transmembrane receptors - the A291V mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Detector | DECTRIS PILATUS 6M |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 41.150, 81.780, 206.730 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.950 - 2.450 |
R-factor | 0.24821 |
Rwork | 0.246 |
R-free | 0.28872 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.014 |
RMSD bond angle | 1.357 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.510 |
High resolution limit [Å] | 2.450 | 2.450 |
Rmerge | 0.060 | 0.550 |
Number of reflections | 27272 | |
<I/σ(I)> | 18.3 | 2.3 |
Completeness [%] | 99.8 | 100 |
Redundancy | 7.2 | 7.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.5 | pH 7.5 |