2XRC
Human complement factor I
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 120 |
Detector technology | CCD |
Collection date | 2009-11-30 |
Detector | ADSC CCD |
Spacegroup name | P 1 |
Unit cell lengths | 71.317, 234.721, 40.300 |
Unit cell angles | 89.98, 90.18, 90.03 |
Refinement procedure
Resolution | 79.000 - 2.690 |
R-factor | 0.20151 |
Rwork | 0.200 |
R-free | 0.23821 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | PDB ENTRIES 1EKB 1by2 1J8E AND 3B4V |
RMSD bond length | 0.006 |
RMSD bond angle | 0.900 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.6.0079) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 79.000 | 2.790 |
High resolution limit [Å] | 2.650 | 2.650 |
Rmerge | 0.110 | 0.410 |
Number of reflections | 68978 | |
<I/σ(I)> | 10.5 | 2 |
Completeness [%] | 90.8 | 90.1 |
Redundancy | 2.9 | 2.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 4 | 20.0-23.5% PEG 1500, 0.1M SODIUM SUCCINATE PH 4.0, 1MM CACL2 |