2WL1
Pyrin PrySpry domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2008-01-26 |
Detector | DECTRIS PILATUS 6M |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 60.270, 60.270, 182.030 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 29.730 - 1.350 |
R-factor | 0.194 |
Rwork | 0.193 |
R-free | 0.21900 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2fbe |
RMSD bond length | 0.010 |
RMSD bond angle | 1.325 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.500 |
High resolution limit [Å] | 1.350 | 1.350 |
Rmerge | 0.090 | 0.410 |
Number of reflections | 42229 | |
<I/σ(I)> | 18.2 | 4.85 |
Completeness [%] | 94.4 | 80 |
Redundancy | 13.1 | 6.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 293 | 0.2M KSCN 25% PEG 2K MME 0.1M TRIS-ACOH, PH 7.5 20C |