Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1991-08-04 |
Detector | RIGAKU IMAGE PLATE |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 113.950, 113.950, 138.050 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 15.660 - 2.710 |
R-factor | 0.174 |
Rwork | 0.171 |
R-free | 0.23400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2ace |
RMSD bond length | 0.030 |
RMSD bond angle | 2.651 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PROTIN |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 15.660 | 2.780 |
High resolution limit [Å] | 2.800 | 2.710 |
Rmerge | 0.150 | |
Number of reflections | 26435 | |
Completeness [%] | 97.5 | |
Redundancy | 4.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |