2VIS
INFLUENZA VIRUS HEMAGGLUTININ, (ESCAPE) MUTANT WITH THR 131 REPLACED BY ILE, COMPLEXED WITH A NEUTRALIZING ANTIBODY
Experimental procedure
Source type | SYNCHROTRON |
Source details | EMBL/DESY, HAMBURG BEAMLINE BW7B |
Synchrotron site | EMBL/DESY, HAMBURG |
Beamline | BW7B |
Detector technology | IMAGE PLATE |
Detector | MARRESEARCH |
Wavelength(s) | 0.85, 1.2 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 85.500, 85.500, 515.000 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 7.000 - 3.250 |
R-factor | 0.188 |
Rwork | 0.188 |
R-free | 0.26700 |
RMSD bond length | 0.012 |
RMSD bond angle | 27.400 * |
Data reduction software | HKL |
Phasing software | X-PLOR (3.84) |
Refinement software | X-PLOR (3.84) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 20.000 |
High resolution limit [Å] | 3.250 |
Rmerge | 0.109 |
Total number of observations | 85445 * |
Number of reflections | 18144 |
Completeness [%] | 96.4 |
Redundancy | 4.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 6 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | reservoir | PEG6000 | 4 (%) | |
10 | 1 | drop | 0.5 (mM) | ||
11 | 1 | drop | 0.05 (%) | ||
2 | 1 | reservoir | MES | 50 (mM) | |
3 | 1 | reservoir | 150 (mM) | ||
4 | 1 | reservoir | 1 (mM) | ||
5 | 1 | reservoir | 0.05 (%) | ||
6 | 1 | drop | protein | 5 (mg/ml) | |
7 | 1 | drop | PEG6000 | 2 (%) | |
8 | 1 | drop | MES | 25 (mM) | |
9 | 1 | drop | 75 (mM) |