Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2003-08-05 |
Detector | CUSTOM (SBC2 3K) |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 148.927, 148.927, 176.398 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 42.990 - 2.750 |
R-factor | 0.146 |
Rwork | 0.144 |
R-free | 0.19100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1jv2 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.997 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC (5.3.0037) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.850 |
High resolution limit [Å] | 2.750 | 2.750 |
Rmerge | 0.140 | 0.600 |
Number of reflections | 62512 | |
<I/σ(I)> | 12.1 | 3 |
Completeness [%] | 99.9 | 100 |
Redundancy | 7.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 277 | 11% PEG 3350, 0.7 M MAGNESIUM ACETATE, 0.1 M SODIUM CACODYLATE, PH 6.5, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 277K |