2QG0

HSP90 complexed with A943037

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-BM
Synchrotron siteAPS
Beamline17-BM
Temperature [K]110
Detector technologyCCD
Collection date2006-03-24
DetectorMAR CCD 165 mm
Wavelength(s)1.0
Spacegroup nameC 1 2 1
Unit cell lengths113.346, 89.144, 64.456
Unit cell angles90.00, 121.45, 90.00
Refinement procedure
Resolution19.860 - 1.850
R-factor0.241
Rwork0.229
R-free0.28500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1yer
RMSD bond length0.005
RMSD bond angle1.200
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareCNX (2002)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.920
High resolution limit [Å]1.8501.850
Number of reflections45919
<I/σ(I)>27.712.8
Completeness [%]98.593.7
Redundancy3.23.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.527740 mg/ml protein with a reservoir solution of 20-28 %(w/v)PEG 3350, 0.1 M Bis-Tris-Propane PH 6.5, 0.2 M Sodium chloride, VAPOR DIFFUSION, HANGING DROP, temperature 277K

218853

PDB entries from 2024-04-24