2OF5
Oligomeric Death Domain complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 110 |
| Detector technology | CCD |
| Collection date | 2006-08-01 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 1.0080 |
| Spacegroup name | P 65 |
| Unit cell lengths | 138.400, 138.400, 207.500 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 30.000 - 3.200 |
| Rwork | 0.236 |
| R-free | 0.27500 |
| Structure solution method | SAD |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SOLVE |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 30.000 |
| High resolution limit [Å] | 3.200 | 3.200 |
| Rmerge | 0.080 | 0.110 |
| Number of reflections | 28927 | |
| <I/σ(I)> | 15 | 2.1 |
| Completeness [%] | 75.0 | 95 |
| Redundancy | 10.3 | 5.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 5.5% PEG 3350, 200mM NaCl and 100mM Na/K phosphate buffer, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 5.5% PEG 3350, 200mM NaCl and 100mM Na/K phosphate buffer, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |