2KWX
The V27A mutant of influenza A M2 proton channel
Spectrometer
Experimental method: SOLUTION NMR
| Spectrometer ID | Spectrometer maker | Spectrometer model | Spectrometer type | Spectrometer field strength |
| 1 | Bruker | AVANCE | Bruker Avance | 600 |
Experiment
| experiment id | conditions id | solution id | Experiment type |
| 1 | 2 | 2 | 2D 1H-15N TROSY |
| 2 | 2 | 2 | 3D TROSY HNCO |
| 3 | 2 | 2 | 3D TROSY HNCA |
| 4 | 2 | 2 | 3D TROSY HN(CO)CA |
| 5 | 2 | 2 | 3D TROSY HNCACB |
| 6 | 1 | 1 | 3D 1H-15N NOESY TROSY |
| 7 | 1 | 1 | 3D 1H-13C NOESY TROSY |
| 8 | 1 | 1 | 2D 1H-13C HSQC |
NMR Sample
| conditions id | NMR sample pH | NMR sample pressure | NMR sample temperature |
| 1 | 7.5 | ambient | 30 |
| 2 | 7.5 | ambient | 30 |
Conformers
| Conformers Calculated Total Number | 75 |
| Conformers Submitted Total Number | 15 |