2J8U
Large CDR3a loop alteration as a function of MHC mutation.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-02-02 |
Detector | MARRESEARCH |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 93.422, 83.893, 122.273 |
Unit cell angles | 90.00, 92.21, 90.00 |
Refinement procedure
Resolution | 122.170 - 2.880 |
R-factor | 0.269 |
Rwork | 0.268 |
R-free | 0.29300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1lp9 |
RMSD bond length | 0.005 |
RMSD bond angle | 0.750 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 3.000 |
High resolution limit [Å] | 2.880 | 2.880 |
Rmerge | 0.080 | 0.420 |
Number of reflections | 38683 | |
<I/σ(I)> | 7 | 1.3 |
Completeness [%] | 94.8 | 69 |
Redundancy | 3.4 | 2.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6.5 | 1.0 M NACL 20% PEG 8000 MES, PH 6.5 |