Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2IX1

RNase II D209N mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
Collection date2004-11-14
DetectorADSC CCD
Spacegroup nameP 65
Unit cell lengths86.316, 86.316, 279.245
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution29.300 - 2.740
R-factor0.187
Rwork0.185
R-free0.22500
Structure solution methodMIRAS
RMSD bond length0.011
RMSD bond angle1.428
Data scaling softwareSCALEPACK
Phasing softwareSHELXCD
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]51.0002.850
High resolution limit [Å]2.7402.740
Rmerge0.0800.640
Number of reflections30737
<I/σ(I)>28.63.4
Completeness [%]99.9100
Redundancy9.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6293VAPOUR DIFFUSION IN SITTING DROPS WITH 1.5 MICRO-L OF PROTEIN SOLUTION, 20 MM TRIS-HCL PH 8, 150 MM NACL, 10% GLYCEROL AND 1 MM DTT, AND 1.5 MICRO-L OF WELL SOLUTION,2.4 M SODIUM MALONATE PH 6.0, AT 293 K

222036

PDB entries from 2024-07-03

PDB statisticsPDBj update infoContact PDBjnumon