Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL24XU |
Synchrotron site | SPring-8 |
Beamline | BL24XU |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2003-10-25 |
Detector | RIGAKU RAXIS V |
Wavelength(s) | 0.8266 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 78.410, 78.410, 137.460 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.790 - 2.500 |
R-factor | 0.22 |
Rwork | 0.218 |
R-free | 0.24600 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | CrystalClear ((MSC/RIGAKU)) |
Data scaling software | CrystalClear ((MSC/RIGAKU)) |
Phasing software | AMoRE |
Refinement software | CNX |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 29.790 |
High resolution limit [Å] | 2.500 |
Number of reflections | 11679 |
Completeness [%] | 75.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | ammonium sulphate, PEG400, MES buffer, pH 6.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K |