Experimental procedure
| Detector technology | IMAGE PLATE | 
| Detector | RIGAKU | 
| Spacegroup name | P 21 21 21 | 
| Unit cell lengths | 65.600, 170.500, 46.700 | 
| Unit cell angles | 90.00, 90.00, 90.00 | 
Refinement procedure
| Resolution | 10.000 - 2.000 | 
| R-factor | 0.178 * | 
| Rwork | 0.178 | 
| RMSD bond length | 0.013 | 
| RMSD bond angle | 0.032 | 
| Phasing software | X-PLOR | 
| Refinement software | PROFFT | 
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 10.000 | 
| High resolution limit [Å] | 2.000 | 
| Rmerge | 0.066 | 
| Total number of observations | 138001 * | 
| Number of reflections | 33397 | 
| Completeness [%] | 91.6 | 
| Redundancy | 4.1 | 
Crystallization Conditions
| crystal ID | method | pH | temperature | details | 
| 1 | Vapor diffusion, hanging drop * | 7.5 * | 4 * | 
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details | 
| 1 | 1 | drop | protein | 1 (%(w/v)) | |
| 2 | 1 | drop | Tris-HCl | 10 (mM) | |
| 3 | 1 | drop | ammonium sulfate | 60 (mg/ml) | |
| 4 | 1 | reservoir | Tris-HCl | 20 (mM) | 