2AGP
Fidelity of Dpo4: effect of metal ions, nucleotide selection and pyrophosphorolysis
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 95 |
Detector technology | IMAGE PLATE |
Collection date | 2004-12-29 |
Detector | RIGAKU RAXIS IV |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 97.867, 101.463, 105.642 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 2.900 |
R-factor | 0.207 |
Rwork | 0.207 |
R-free | 0.26400 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Refinement software | CNS |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 30.000 | 30.000 | 3.000 |
High resolution limit [Å] | 2.900 | 6.230 | 2.900 |
Rmerge | 0.064 | 0.026 | 0.354 |
Number of reflections | 22606 | ||
Completeness [%] | 93.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |