2ZDV
Exploring Thrombin S1 pocket
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 110 |
Detector technology | CCD |
Collection date | 2007-03-17 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 0.97803 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 70.500, 71.400, 72.800 |
Unit cell angles | 90.00, 100.60, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.720 |
R-factor | 0.1885 |
Rwork | 0.187 |
R-free | 0.24300 |
Structure solution method | AB INITIO PHASING |
Starting model (for MR) | 1h8d |
RMSD bond length | 0.008 |
RMSD bond angle | 0.026 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHELX |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.000 | 1.780 |
High resolution limit [Å] | 1.720 | 1.720 |
Number of reflections | 37058 | |
<I/σ(I)> | 27.5 | 3.6 |
Completeness [%] | 98.4 | 94.8 |
Redundancy | 2.9 | 2.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | Phosphate Buffer, Sodium Chloride, PEG 8000, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |