2Y7Q
THE HIGH-AFFINITY COMPLEX BETWEEN IGE AND ITS RECEPTOR FC EPSILON RI
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID29 |
| Synchrotron site | ESRF |
| Beamline | ID29 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Detector | ADSC CCD |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 99.491, 103.341, 110.122 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 37.680 - 3.400 |
| R-factor | 0.248 |
| Rwork | 0.245 |
| R-free | 0.29200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | PDB ENTRIES 1F6A AND 1O0V |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.104 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 37.000 | 3.490 |
| High resolution limit [Å] | 3.400 | 3.400 |
| Rmerge | 0.250 | |
| Number of reflections | 16204 | |
| <I/σ(I)> | 8.5 | 1.6 |
| Completeness [%] | 99.9 | 99.9 |
| Redundancy | 5.9 | 6.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | SITTING DROP VAPOR DIFFUSION. RESERVOIR SOLUTION CONTAINED 2.8M SODIUM ACETATE PH 7. |