2Y21
The mechanisms of HAMP-mediated signaling in transmembrane receptors - the A291V mutant
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Detector | DECTRIS PILATUS 6M |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 41.150, 81.780, 206.730 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.950 - 2.450 |
| R-factor | 0.24821 |
| Rwork | 0.246 |
| R-free | 0.28872 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.357 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.510 |
| High resolution limit [Å] | 2.450 | 2.450 |
| Rmerge | 0.060 | 0.550 |
| Number of reflections | 27272 | |
| <I/σ(I)> | 18.3 | 2.3 |
| Completeness [%] | 99.8 | 100 |
| Redundancy | 7.2 | 7.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 7.5 | pH 7.5 |