2RK2
DHFR R-67 complexed with NADP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-07-30 |
Detector | RIGAKU SATURN 92 |
Wavelength(s) | 1.5418 |
Spacegroup name | I 41 2 2 |
Unit cell lengths | 67.520, 67.520, 52.070 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 22.860 - 1.900 |
R-factor | 0.14403 |
Rwork | 0.141 |
R-free | 0.19991 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2rh2 |
RMSD bond length | 0.023 |
RMSD bond angle | 2.295 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | CNS |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.970 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.115 | 0.219 |
Number of reflections | 4883 | |
<I/σ(I)> | 13 | 4.5 |
Completeness [%] | 97.8 | 83.7 |
Redundancy | 6.4 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 277 | 50% 2-methyl-2,4-pentanediol (MPD), 100 mM Tris, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K |