2NO6

C4S dCK variant of dCK in complex with FTC+ADP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-BM
Synchrotron siteAPS
Beamline22-BM
Temperature [K]100
Detector technologyCCD
Collection date2005-11-20
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1.0
Spacegroup nameC 2 2 21
Unit cell lengths52.790, 134.330, 154.980
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution30.000 - 1.900
R-factor0.19168
Rwork0.187
R-free0.23452
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1p5z
RMSD bond length0.017
RMSD bond angle1.723
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.000
High resolution limit [Å]1.9001.900
Number of reflections43616
<I/σ(I)>16.73.8
Completeness [%]99.396.4
Redundancy10.19.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5298Reservoir containing 0.95-1.5M trisodium citrate dihydrate and 100mM HEPES, pH 7.5., VAPOR DIFFUSION, HANGING DROP, temperature 298K