The leupeptin-trypsin covalent complex at 1.14 A resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]100
Detector technologyCCD
Collection date2003-10-17
DetectorADSC QUANTUM 4
Wavelength(s)1.00000
Spacegroup nameP 21 21 21
Unit cell lengths61.888, 63.562, 69.102
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.630 - 1.140
R-factor0.117
Rwork0.116
R-free0.13800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2age
RMSD bond length0.017
RMSD bond angle1.869
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareEPMR
Refinement softwareREFMAC (5.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.6301.200
High resolution limit [Å]1.1401.140
Rmerge0.0400.284
Number of reflections88464
<I/σ(I)>13.11.5
Completeness [%]99.6
Redundancy3.21.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6298ammonium sulfate, bis-tris propane, calcium chloride, benzamidine, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219869

PDB entries from 2024-05-15