1TG3
Effect of Shuttle Location and pH Environment on H+ Transfer in Human Carbonic Anhydrase II
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 293 |
Detector technology | IMAGE PLATE |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.54 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 42.839, 41.629, 72.949 |
Unit cell angles | 90.00, 104.75, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.800 |
Rwork | 0.171 |
R-free | 0.20600 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2cba |
Data scaling software | SCALEPACK |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 1.830 |
High resolution limit [Å] | 1.800 | 1.800 |
Number of reflections | 22162 | |
Completeness [%] | 91.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |