1MU8

thrombin-hirugen_l-378,650

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]290
Detector technologyIMAGE PLATE
Collection date1998
DetectorRIGAKU RAXIS II
Wavelength(s)1.5418
Spacegroup nameC 1 2 1
Unit cell lengths71.120, 72.230, 73.030
Unit cell angles90.00, 100.80, 90.00
Refinement procedure
Resolution25.000 - 2.000
R-factor0.2088
Rwork0.239
Structure solution methodFOURIER SYNTHESIS
Data scaling softwareSCALEPACK
Refinement softwareCNX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.00025.942
High resolution limit [Å]2.0002.000
Number of reflections23202
Completeness [%]94.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.3295pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 295K

218853

PDB entries from 2024-04-24