Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1MMP

MATRILYSIN COMPLEXED WITH CARBOXYLATE INHIBITOR

Experimental procedure
Detector technologyIMAGE PLATE
Collection date1993-08-27
DetectorMARRESEARCH
Wavelength(s)1.5418
Spacegroup nameP 32 2 1
Unit cell lengths62.000, 62.000, 175.700
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution6.000 - 2.400

*

R-factor0.18
Rwork0.180
RMSD bond length0.013
RMSD bond angle2.760
Data reduction softwareMOSFLM (V. 5.1.2)
Phasing softwareX-PLOR (3.1)
Refinement softwareX-PLOR (3.1)
Data quality characteristics
 Overall
High resolution limit [Å]2.400

*

Rmerge0.090
Total number of observations80416

*

Number of reflections15769
Completeness [%]86.2
Redundancy5.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

6.5

*

17-25

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein10 (mg/ml)
21dropinhibitor1.2 (mM)
31dropDMSO2.5 (%)
41reservoirsodium citrate0.2 (M)
51reservoircacodylate0.1 (M)
61reservoir2-propanol30 (%)

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon