Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1MAS

PURINE NUCLEOSIDE HYDROLASE

Experimental procedure
Detector technologyAREA DETECTOR
Collection date1995-01-24
DetectorSIEMENS
Spacegroup nameP 21 21 2
Unit cell lengths63.840, 131.530, 90.100
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution99.000 - 2.500
R-factor0.17

*

Rwork0.170
RMSD bond length0.016
RMSD bond angle1.510

*

Data reduction softwareXENGEN (V. 2.1)
Phasing softwareX-PLOR
Refinement softwareTNT
Data quality characteristics
 Overall
Low resolution limit [Å]99.000
High resolution limit [Å]2.500
Rmerge0.075

*

Number of reflections25989
Completeness [%]96.1
Redundancy4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

7.4

*

22

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein34 (mg/ml)
21dropphosphate10 (mM)
31dropglycine10 (mM)
41reservoirpotassium citrate100 (mM)
51reservoirPEG40008 (%)
61reservoirsodium azide0.05 (%)

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon