1LPH
LYS(B28)PRO(B29)-HUMAN INSULIN
Experimental procedure
Detector technology | IMAGE PLATE |
Collection date | 1994-06-09 |
Detector | RIGAKU RAXIS IIC |
Spacegroup name | H 3 |
Unit cell lengths | 79.620, 79.620, 37.780 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 8.000 - 2.300 |
R-factor | 0.161 |
Rwork | 0.161 |
RMSD bond length | 0.016 * |
RMSD bond angle | 0.054 * |
Data reduction software | RIGAKU |
Phasing software | X-PLOR (3.1) |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 38.500 |
High resolution limit [Å] | 2.300 |
Rmerge | 0.060 |
Total number of observations | 19299 * |
Number of reflections | 3910 |
Completeness [%] | 83.4 |
Redundancy | 5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | unknown * | 5.9 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | 1 | human insulin | 0.27 (mM) | |
2 | 1 | 1 | hydrochloric acid | 0.12 (M) | |
3 | 1 | 1 | sodium citrate | 0.05 (M) |