Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1G29

MALK

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE BW7B
Synchrotron siteEMBL/DESY, HAMBURG
BeamlineBW7B
Temperature [K]100
Detector technologyCCD
Collection date2000-03-09
DetectorMARRESEARCH
Wavelength(s)0.8424
Spacegroup nameP 21 21 2
Unit cell lengths190.718, 65.705, 77.912
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.260 - 1.900
Rwork0.211
R-free0.24700
Structure solution methodMAD
RMSD bond length0.017
RMSD bond angle1.800
Data scaling softwareXDS
Phasing softwareSHARP
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.2601.880
High resolution limit [Å]1.8601.860
Rmerge0.0360.235
Number of reflections82679
<I/σ(I)>24.64.5
Completeness [%]99.093.8
Redundancy4.63
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.518

*

2M ammonium sulfate, 5% dioxane, 100mM Tris, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 297K
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein1 (mM)
21dropADP1 (mM)
31dropreservoir
41reservoirammonium sulfate2 (M)
51reservoirdioxane5 (%)
61reservoirTris-HCl100 (mM)

226707

PDB entries from 2024-10-30