Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1EEA

Acetylcholinesterase

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Temperature [K]298
Detector technologyAREA DETECTOR
Collection date1987-01-15
DetectorXENTRONICS
Spacegroup nameF 2 2 2
Unit cell lengths140.860, 201.460, 235.770
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution? - 4.500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2ace
Data reduction softwareX-GEN
Data scaling softwareX-GEN
Phasing softwareX-PLOR
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.3004.650
High resolution limit [Å]4.5004.500
Rmerge0.0970.272
Number of reflections9717
<I/σ(I)>6.72
Completeness [%]95.375.2
Redundancy3.21.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
18pH 8.0

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon