Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1TP0

Triple mutation in interleukin 1 beta cavity:replacement of phenylalanines with tryptophan.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]298
Detector technologyCCD
Collection date2001-05-12
DetectorMARRESEARCH
Wavelength(s)1.5418
Spacegroup nameP 43
Unit cell lengths54.970, 54.970, 76.890
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution76.900 - 2.200
R-factor0.206
Rwork0.205
R-free0.23700
Structure solution methodMOLECULAR REPLACEMENT
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 Overall
Low resolution limit [Å]76.900
High resolution limit [Å]2.200
Number of reflections10627
Completeness [%]91.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.429829% AMMONIUM SULFATE W/V, 100 MM TRIS, pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon