1MAS
PURINE NUCLEOSIDE HYDROLASE
Experimental procedure
Detector technology | AREA DETECTOR |
Collection date | 1995-01-24 |
Detector | SIEMENS |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 63.840, 131.530, 90.100 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 99.000 - 2.500 |
R-factor | 0.17 * |
Rwork | 0.170 |
RMSD bond length | 0.016 |
RMSD bond angle | 1.510 * |
Data reduction software | XENGEN (V. 2.1) |
Phasing software | X-PLOR |
Refinement software | TNT |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 99.000 |
High resolution limit [Å] | 2.500 |
Rmerge | 0.075 * |
Number of reflections | 25989 |
Completeness [%] | 96.1 |
Redundancy | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 7.4 * | 22 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 34 (mg/ml) | |
2 | 1 | drop | phosphate | 10 (mM) | |
3 | 1 | drop | glycine | 10 (mM) | |
4 | 1 | reservoir | potassium citrate | 100 (mM) | |
5 | 1 | reservoir | PEG4000 | 8 (%) | |
6 | 1 | reservoir | sodium azide | 0.05 (%) |