1KEG
Antibody 64M-2 Fab complexed with dTT(6-4)TT
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | MACSCIENCE |
| Temperature [K] | 277 |
| Detector technology | IMAGE PLATE |
| Collection date | 1998-01-01 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 73.567, 137.274, 49.615 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 10.000 - 2.400 |
| R-factor | 0.207 |
| Rwork | 0.201 |
| R-free | 0.26800 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ehl |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.440 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR (3.843) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 29.600 | 2.490 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Rmerge | 0.077 | 0.304 |
| Number of reflections | 17570 | |
| <I/σ(I)> | 21.8 | 3 |
| Completeness [%] | 92.0 | 85.8 |
| Redundancy | 5 | 4.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | PEG 8000, nickel chloride, Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
Crystallization Reagents
| ID | crystal ID | solution ID | reagent name | concentration | details |
| 1 | 1 | 1 | PEG 8000 | ||
| 2 | 1 | 1 | NiCl2 | ||
| 3 | 1 | 1 | Tris-HCl |