Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1GNS

SUBTILISIN BPN'

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]293
Detector technologyAREA DETECTOR
Collection date1994-07-15
DetectorSIEMENS
Spacegroup nameP 1 21 1
Unit cell lengths41.170, 78.060, 36.700
Unit cell angles90.00, 114.60, 90.00
Refinement procedure
Resolution8.000 - 1.800
R-factor0.165
Rwork0.165
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1suc
RMSD bond length0.020
RMSD bond angle0.040
Data reduction softwareXENGEN
Data scaling softwareXENGEN
Phasing softwareAMoRE
Refinement softwarePROLSQ
Data quality characteristics
 Overall
Low resolution limit [Å]8.000
High resolution limit [Å]1.800
Rmerge0.055
Total number of observations64819

*

Number of reflections15590
Completeness [%]77.0
Redundancy3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

9

*

20

*

55% ACETONE, 0.05M GLYCINE PH 9.0
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein10 (mg/ml)
21dropglycine0.05 (M)pH9.0
31reservoiracetone55 (%)
41reservoirglycine0.05 (M)

219869