5TJH
hUGDH A136M Substitution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 77 |
Detector technology | CCD |
Collection date | 2015-11-14 |
Detector | RAYONIX MX300-HS |
Wavelength(s) | 1 |
Spacegroup name | P 1 |
Unit cell lengths | 92.350, 104.590, 107.710 |
Unit cell angles | 64.82, 68.35, 73.72 |
Refinement procedure
Resolution | 37.173 - 2.050 |
R-factor | 0.1725 |
Rwork | 0.171 |
R-free | 0.20300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4rjt |
RMSD bond length | 0.008 |
RMSD bond angle | 0.893 |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 37.180 |
High resolution limit [Å] | 2.050 |
Number of reflections | 206192 |
<I/σ(I)> | 7.8 |
Completeness [%] | 91.3 |
Redundancy | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 12% PEG 3350,0.2M NaCl, 0.1M Tris buffer pH 7.6 |