YgjD(V85E)-YeaZ heterodimer in complex with ATP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]173
Detector technologyPIXEL
Collection date2012-12-07
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.999
Spacegroup nameP 1
Unit cell lengths63.690, 68.080, 87.340
Unit cell angles109.31, 92.56, 117.94
Refinement procedure
Resolution42.620 - 2.330
R-factor0.1825
Rwork0.180
R-free0.23323
RMSD bond length0.012
RMSD bond angle1.313
Refinement softwareREFMAC (5.8.0071)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.330
Number of reflections48866
<I/σ(I)>13.06
Completeness [%]96.0
Redundancy3.34
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.1M HEPES pH 7.5, 26% PEG4000, 0.3 M Lithium Sulfate and 0.1 Sodium Acetate

221051