Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

7PF1

UVC treated Human apoferritin

Summary for 7PF1
Entry DOI10.2210/pdb7pf1/pdb
EMDB information13364
DescriptorFerritin heavy chain, N-terminally processed, CHLORIDE ION, MAGNESIUM ION, ... (4 entities in total)
Functional Keywordsferritin, metal binding protein
Biological sourceHomo sapiens (Human)
Total number of polymer chains24
Total formula weight494055.30
Authors
Renault, L.,Depelteau, J.S.,Briegel, A. (deposition date: 2021-08-11, release date: 2022-01-26, Last modification date: 2024-07-17)
Primary citationDepelteau, J.S.,Renault, L.,Althof, N.,Cassidy, C.K.,Mendonca, L.M.,Jensen, G.J.,Resch, G.P.,Briegel, A.
UVC inactivation of pathogenic samples suitable for cryo-EM analysis.
Commun Biol, 5:29-29, 2022
Cited by
PubMed Abstract: Cryo-electron microscopy has become an essential tool to understand structure and function of biological samples. Especially for pathogens, such as disease-causing bacteria and viruses, insights gained by cryo-EM can aid in developing cures. However, due to the biosafety restrictions of pathogens, samples are often treated by chemical fixation to render the pathogen inert, affecting the ultrastructure of the sample. Alternatively, researchers use in vitro or ex vivo models, which are non-pathogenic but lack the complexity of the pathogen of interest. Here we show that ultraviolet-C (UVC) radiation applied at cryogenic temperatures can be used to eliminate or dramatically reduce the infectivity of Vibrio cholerae and the bacterial virus, the ICP1 bacteriophage. We show no discernable structural impact of this treatment of either sample using two cryo-EM methods: cryo-electron tomography followed by sub-tomogram averaging, and single particle analysis (SPA). Additionally, we applied the UVC irradiation to the protein apoferritin (ApoF), which is a widely used test sample for high-resolution SPA studies. The UVC-treated ApoF sample resulted in a 2.1 Å structure indistinguishable from an untreated published map. This research demonstrates that UVC treatment is an effective and inexpensive addition to the cryo-EM sample preparation toolbox.
PubMed: 35017666
DOI: 10.1038/s42003-021-02962-w
PDB entries with the same primary citation
Experimental method
ELECTRON MICROSCOPY (2.1 Å)
Structure validation

246704

PDB entries from 2025-12-24

PDB statisticsPDBj update infoContact PDBjnumon