Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6NCT

Structure of p110alpha/niSH2 - vector data collection

Summary for 6NCT
Entry DOI10.2210/pdb6nct/pdb
Related4OVU
DescriptorPhosphatidylinositol 4,5-bisphosphate 3-kinase catalytic subunit alpha isoform, Phosphatidylinositol 3-kinase regulatory subunit alpha, TRIS-HYDROXYMETHYL-METHYL-AMMONIUM, ... (4 entities in total)
Functional Keywordspi3k, kinase, phosphatidylinositol 4, 5-bisphosphate 3-kinase alpha isoform, p110, p85, transferase
Biological sourceHomo sapiens (Human)
More
Total number of polymer chains2
Total formula weight162022.01
Authors
Miller, M.S.,Maheshwari, S.,Amzel, L.M.,Gabelli, S.B. (deposition date: 2018-12-12, release date: 2019-02-06, Last modification date: 2023-10-11)
Primary citationMiller, M.S.,Maheshwari, S.,Shi, W.,Gao, Y.,Chu, N.,Soares, A.S.,Cole, P.A.,Amzel, L.M.,Fuchs, M.R.,Jakoncic, J.,Gabelli, S.B.
Getting the Most Out of Your Crystals: Data Collection at the New High-Flux, Microfocus MX Beamlines at NSLS-II.
Molecules, 24:-, 2019
Cited by
PubMed Abstract: Advances in synchrotron technology are changing the landscape of macromolecular crystallography. The two recently opened beamlines at NSLS-II-AMX and FMX-deliver high-flux microfocus beams that open new possibilities for crystallographic data collection. They are equipped with state-of-the-art experimental stations and automation to allow data collection on previously intractable crystals. Optimized data collection strategies allow users to tailor crystal positioning to optimally distribute the X-ray dose over its volume. Vector data collection allows the user to define a linear trajectory along a well diffracting volume of the crystal and perform rotational data collection while moving along the vector. This is particularly well suited to long, thin crystals. We describe vector data collection of three proteins-Akt1, PI3Kα, and CDP-Chase-to demonstrate its application and utility. For smaller crystals, we describe two methods for multicrystal data collection in a single loop, either manually selecting multiple centers (using H108A-PHM as an example), or "raster-collect", a more automated approach for a larger number of crystals (using CDP-Chase as an example).
PubMed: 30704096
DOI: 10.3390/molecules24030496
PDB entries with the same primary citation
Experimental method
X-RAY DIFFRACTION (3.35 Å)
Structure validation

229183

PDB entries from 2024-12-18

PDB statisticsPDBj update infoContact PDBjnumon