5PV5
PanDDA analysis group deposition -- Crystal Structure of BRD1 after initial refinement with no ligand modelled (structure 219)
Summary for 5PV5
Entry DOI | 10.2210/pdb5pv5/pdb |
Group deposition | PanDDA analysis group deposition of models of ground state datasets (G_1002023) |
Descriptor | Bromodomain-containing protein 1, 1,2-ETHANEDIOL, SODIUM ION, ... (4 entities in total) |
Functional Keywords | pandda, sgc - diamond i04-1 fragment screening, bromodomain, epigenetics, xchemexplorer, gene regulation |
Biological source | Homo sapiens (Human) |
Cellular location | Nucleus : O95696 |
Total number of polymer chains | 2 |
Total formula weight | 36720.62 |
Authors | Pearce, N.M.,Krojer, T.,Talon, R.,Bradley, A.R.,Fairhead, M.,Sethi, R.,Wright, N.,MacLean, E.,Collins, P.,Brandao-Neto, J.,Douangamath, A.,Renjie, Z.,Dias, A.,Ng, J.,Brennan, P.E.,Cox, O.,Bountra, C.,Arrowsmith, C.H.,Edwards, A.,von Delft, F. (deposition date: 2017-02-07, release date: 2017-03-29, Last modification date: 2024-03-06) |
Primary citation | Pearce, N.M.,Krojer, T.,Bradley, A.R.,Collins, P.,Nowak, R.P.,Talon, R.,Marsden, B.D.,Kelm, S.,Shi, J.,Deane, C.M.,von Delft, F. A multi-crystal method for extracting obscured crystallographic states from conventionally uninterpretable electron density. Nat Commun, 8:15123-15123, 2017 Cited by PubMed Abstract: In macromolecular crystallography, the rigorous detection of changed states (for example, ligand binding) is difficult unless signal is strong. Ambiguous ('weak' or 'noisy') density is experimentally common, since molecular states are generally only fractionally present in the crystal. Existing methodologies focus on generating maximally accurate maps whereby minor states become discernible; in practice, such map interpretation is disappointingly subjective, time-consuming and methodologically unsound. Here we report the PanDDA method, which automatically reveals clear electron density for the changed state-even from inaccurate maps-by subtracting a proportion of the confounding 'ground state'; changed states are objectively identified from statistical analysis of density distributions. The method is completely general, implying new best practice for all changed-state studies, including the routine collection of multiple ground-state crystals. More generally, these results demonstrate: the incompleteness of atomic models; that single data sets contain insufficient information to model them fully; and that accuracy requires further map-deconvolution approaches. PubMed: 28436492DOI: 10.1038/ncomms15123 PDB entries with the same primary citation |
Experimental method | X-RAY DIFFRACTION (1.68 Å) |
Structure validation
Download full validation report