9YCU

Protiated human DJ-1, 100K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]100
Detector technologyPIXEL
Collection date2020-10-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.729
Spacegroup nameP 31 2 1
Unit cell lengths75.109, 75.109, 75.505
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution37.550 - 1.050
R-factor0.1187
Rwork0.118
R-free0.13420
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.083
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.21.2_5419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]37.7501.070
High resolution limit [Å]1.0501.050
Rmeas0.0753.838
Number of reflections1148195635
<I/σ(I)>13.20.6
Completeness [%]100.099.6
Redundancy10.610.2
CC(1/2)0.9990.252
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529522-24% PEG 3000, 200 mM NaCl, and 100 mM HEPES, pH 7.5

248335