Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9WIU

SbSOMT in apo state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL10U2
Synchrotron siteSSRF
BeamlineBL10U2
Temperature [K]100
Detector technologyPIXEL
Collection date2024-06-17
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.979
Spacegroup nameP 21 21 21
Unit cell lengths84.393, 160.067, 200.964
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution80.162 - 2.040
Rwork0.227
R-free0.24690
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.505
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0430 (refmacat 0.4.126))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]200.960200.9602.070
High resolution limit [Å]2.04011.1702.040
Rmerge0.2480.0627.020
Rmeas0.2690.0697.703
Rpim0.1030.0293.130
Number of reflections17223512068501
<I/σ(I)>6.815.21
Completeness [%]99.398.8100
Redundancy13.29.111.3
CC(1/2)0.9950.9920.389
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.2 M Sodium Malonate pH 7.0, 20% PEG 3350, 10% Glycerol

255900

PDB entries from 2026-07-01

PDB statisticsPDBj update infoContact PDBjnumon