Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9UM5

CaPETaseM9 SEC loop of 10CL variant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPAL/PLS BEAMLINE 7A (6B, 6C1)
Synchrotron sitePAL/PLS
Beamline7A (6B, 6C1)
Temperature [K]100
Detector technologyPIXEL
Collection date2023-11-29
DetectorDECTRIS EIGER2 S 9M
Wavelength(s)0.97934
Spacegroup nameP 1
Unit cell lengths46.574, 75.778, 77.244
Unit cell angles118.73, 95.89, 102.03
Refinement procedure
Resolution25.830 - 1.730
R-factor0.18508
Rwork0.183
R-free0.22458
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7yme
RMSD bond length0.007
RMSD bond angle1.689
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0425)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.790
High resolution limit [Å]1.7301.730
Rmerge0.153
Number of reflections876268387
<I/σ(I)>11.8
Completeness [%]94.9
Redundancy3.37
CC(1/2)0.995
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29315% (w/v) PEG 3350, 0.1 M Magnesium formate dihydrate

254917