Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9U50

GDP-bound KRAS G12V in complex with MCB-294

This is a non-PDB format compatible entry.
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSRRC BEAMLINE BL15A1
Synchrotron siteNSRRC
BeamlineBL15A1
Temperature [K]100
Detector technologyCCD
Collection date2025-02-27
DetectorRAYONIX MX-300
Wavelength(s)1
Spacegroup nameP 1 21 1
Unit cell lengths47.326, 103.188, 56.651
Unit cell angles90.00, 107.28, 90.00
Refinement procedure
Resolution23.970 - 1.870
R-factor0.18355
Rwork0.181
R-free0.22777
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.012
RMSD bond angle1.761
Data reduction softwareSAINT
Data scaling softwareSAINT
Phasing softwarePHASER (2.8.2)
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0001.940
High resolution limit [Å]1.8701.870
Rmerge0.0590.480
Number of reflections425594014
<I/σ(I)>23.75
Completeness [%]99.3
Redundancy4.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52980.2 M sodium acetate, 0.1 M Tris, pH 8.5, 26% (w/v) PEG 3350.

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon