RCSB PDBPDBeBMRBAdv. SearchSearch help

9T6J

Complement C5 re-refined

Replaces:  3CU7
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX II BEAMLINE I711
Synchrotron siteMAX II
BeamlineI711
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1998-10-20
DetectorMAR scanner 345 mm plate
Wavelength(s)0.989
Spacegroup nameP 31
Unit cell lengths144.260, 144.260, 241.000
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution29.290 - 3.110
R-factor0.236
Rwork0.234
R-free0.26860
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle0.749
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.21.2_5419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0003.210
High resolution limit [Å]3.1003.100
Rmerge0.0400.570
Number of reflections986008671
<I/σ(I)>13.51.3
Completeness [%]96.9
Redundancy1.36
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION6.8277100 mM NaCl, MES pH 6.8

257629