9S8A

Amuc0451_S1_20

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2022-01-31
DetectorDECTRIS EIGER2 S 16M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths113.660, 59.900, 123.720
Unit cell angles90.00, 115.75, 90.00
Refinement procedure
Resolution51.754 - 1.600
Rwork0.156
R-free0.19150
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.681
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0430 (refmacat 0.4.105))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]59.9001.630
High resolution limit [Å]1.6001.600
Number of reflections129115955288
<I/σ(I)>10.31.4
Completeness [%]100.0
Redundancy6.5
CC(1/2)0.9980.549
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29820 % w/v PEG 3350, 0.1 M Bis-Tris propane 7.5, 0.02 M Sodium/potassium phosphate 40 mg/ml Amuc0451