9S06

Dark-state of CBD of TtCarH (TR-SFX, SACLA)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeFREE ELECTRON LASER
Source detailsSACLA BEAMLINE BL2
Synchrotron siteSACLA
BeamlineBL2
Temperature [K]293.15
Detector technologyCCD
Collection date2022-11-01
DetectorMPCCD
Wavelength(s)1.55
Spacegroup nameP 21 21 21
Unit cell lengths64.800, 71.090, 207.260
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.000 - 2.050
R-factor0.1764
Rwork0.174
R-free0.21900
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.991
Data reduction softwareCrystFEL (0.10.1)
Data scaling softwareCrystFEL (0.10.1)
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.100
High resolution limit [Å]2.0502.050
Number of reflections611054014
<I/σ(I)>22.831.87
Completeness [%]100.0100
Redundancy129039207
CC(1/2)1.0000.700
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE7.5293.150.1 M HEPES pH 7.5, 20% PEG 10000.

248942

PDB entries from 2026-02-11

PDB statisticsPDBj update infoContact PDBjnumon