Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-06-05 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.0 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 97.800, 81.760, 51.720 |
Unit cell angles | 90.00, 114.67, 90.00 |
Refinement procedure
Resolution | 47.004 - 1.250 |
Rwork | 0.151 |
R-free | 0.17640 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.815 |
Data reduction software | autoPROC |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.004 | 1.304 |
High resolution limit [Å] | 1.244 | 1.244 |
Rmerge | 0.043 | 0.379 |
Rpim | 0.027 | 0.258 |
Number of reflections | 85942 | 4297 |
<I/σ(I)> | 12.4 | 2.2 |
Completeness [%] | 95.4 | |
Redundancy | 3.4 | |
CC(1/2) | 1.000 | 0.858 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 30mM sodium nitrate, 30mM disodium hydrogen phosphate, 30mM ammonium sulfate, 100mM MES-imidazole pH 6.5, 20%(w/v) PEG 550 MME, 10%(w/v) PEG 20K (Morpheus condition C1) |