Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-05-20 |
| Detector | DECTRIS EIGER2 XE 16M |
| Wavelength(s) | 0.9763 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 67.660, 67.890, 138.030 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 39.360 - 1.980 |
| R-factor | 0.2129 |
| Rwork | 0.211 |
| R-free | 0.24080 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.078 |
| Data reduction software | xia2 |
| Data scaling software | xia2 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.21-5207-000)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 60.750 | 2.010 |
| High resolution limit [Å] | 1.980 | 1.980 |
| Number of reflections | 45133 | 2211 |
| <I/σ(I)> | 9.6 | 0.4 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 13.5 | 13.7 |
| CC(1/2) | 1.000 | 0.300 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 1.26 M sodium phosphate monobasic, 0.14 M potassium phosphate dibasic |