Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-1 |
| Synchrotron site | ESRF |
| Beamline | ID23-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-05-06 |
| Detector | DECTRIS EIGER2 X 9M |
| Wavelength(s) | 0.8856 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 67.489, 68.031, 138.117 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.460 - 1.910 |
| R-factor | 0.1929 |
| Rwork | 0.191 |
| R-free | 0.22760 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.126 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.21-5207-000)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.460 | 1.950 |
| High resolution limit [Å] | 1.910 | 1.910 |
| Number of reflections | 48906 | 3260 |
| <I/σ(I)> | 9.6 | 1.6 |
| Completeness [%] | 97.9 | 98 |
| Redundancy | 4.4 | 3.9 |
| CC(1/2) | 0.996 | 0.628 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 1.26 M sodium phosphate monobasic, 0.14 M potassium phosphate dibasic |